Поиск :
Личный кабинет :
Электронный каталог: Li, R. - Data Sorting Modes of Phoswich Detector Array
Li, R. - Data Sorting Modes of Phoswich Detector Array

Статья
Автор: Li, R.
Nuclear Instruments & Methods in Physics Research A: Data Sorting Modes of Phoswich Detector Array
б.г.
ISBN отсутствует
Автор: Li, R.
Nuclear Instruments & Methods in Physics Research A: Data Sorting Modes of Phoswich Detector Array
б.г.
ISBN отсутствует
Статья
Li, R.
Data Sorting Modes of Phoswich Detector Array / R.Li, S.Stukalov, [a.o.]. – Text : electronic // Nuclear Instruments & Methods in Physics Research A. – 2026. – Vol. 1086. – P. 171337. – URL: https://doi.org/10.1016/j.nima.2026.171337. – Bibliogr.: 29.
The different data-sorting modes of the phoswich detector array PARIS used for detecting high-energy (4−10 MeV) *g rays are investigated. The characteristics including time resolution, energy resolution and detection efficiency under various modes are studied. The present study shows that PARIS has capabilities of rejecting escape and pileup events when used for decay spectroscopy. Notably, the methods presented in this work refer specifically to the *b-decay experiment of 80&sup(g+m)Ga conducted with three PARIS clusters comprising 27 phoswich detectors, rather than to a general report on the PARIS array or its overall performance for in-beam spectroscopy. Compared with the 2’’×2’’×2’’ LaBr&sub(3) (Ce) detector (Ciemała et al., 2009), even in individual mode, PARIS provides significant suppression of single- and double-escape peaks and reduces background via vetoing function of the outer-volume NaI(Tl) crystals. In contrast to the common approach of adding back the energies in LaBr&sub(3) (Ce) and NaI(Tl) to increase the detection efficiency of the full-energy peak, using NaI(Tl) as a veto shield provides a superior trade-off for applications where spectral purity is essential. Employing add-back analysis within each cluster of nine phoswiches or between all phoswiches could enhance full-energy peak efficiency and further suppress escape peaks and background. Applying a multiplicity condition provides a further suppression but simultaneously lowers the statistics of full-energy peaks.
ОИЯИ = ОИЯИ (JINR)2026
Li, R.
Data Sorting Modes of Phoswich Detector Array / R.Li, S.Stukalov, [a.o.]. – Text : electronic // Nuclear Instruments & Methods in Physics Research A. – 2026. – Vol. 1086. – P. 171337. – URL: https://doi.org/10.1016/j.nima.2026.171337. – Bibliogr.: 29.
The different data-sorting modes of the phoswich detector array PARIS used for detecting high-energy (4−10 MeV) *g rays are investigated. The characteristics including time resolution, energy resolution and detection efficiency under various modes are studied. The present study shows that PARIS has capabilities of rejecting escape and pileup events when used for decay spectroscopy. Notably, the methods presented in this work refer specifically to the *b-decay experiment of 80&sup(g+m)Ga conducted with three PARIS clusters comprising 27 phoswich detectors, rather than to a general report on the PARIS array or its overall performance for in-beam spectroscopy. Compared with the 2’’×2’’×2’’ LaBr&sub(3) (Ce) detector (Ciemała et al., 2009), even in individual mode, PARIS provides significant suppression of single- and double-escape peaks and reduces background via vetoing function of the outer-volume NaI(Tl) crystals. In contrast to the common approach of adding back the energies in LaBr&sub(3) (Ce) and NaI(Tl) to increase the detection efficiency of the full-energy peak, using NaI(Tl) as a veto shield provides a superior trade-off for applications where spectral purity is essential. Employing add-back analysis within each cluster of nine phoswiches or between all phoswiches could enhance full-energy peak efficiency and further suppress escape peaks and background. Applying a multiplicity condition provides a further suppression but simultaneously lowers the statistics of full-energy peaks.
ОИЯИ = ОИЯИ (JINR)2026
На полку