Поиск :
Личный кабинет :
Электронный каталог: Mai, A. - Calibration Technique for Stilbene-Based Neutron Detector
Mai, A. - Calibration Technique for Stilbene-Based Neutron Detector

Статья
Автор: Mai, A.
Физика элементарных частиц и атомного ядра. Письма: Calibration Technique for Stilbene-Based Neutron Detector : Abstract
б.г.
ISBN отсутствует
Автор: Mai, A.
Физика элементарных частиц и атомного ядра. Письма: Calibration Technique for Stilbene-Based Neutron Detector : Abstract
б.г.
ISBN отсутствует
Статья
Mai, A.
Calibration Technique for Stilbene-Based Neutron Detector : Abstract / A.Mai, M.S.Golovkov, A.A.Bezbakh, G.Kaminski, R.Turar // Физика элементарных частиц и атомного ядра. Письма. – 2025. – Т. 22, № 5. – P. 1032. – URL: https://www1.jinr.ru/Pepan_letters/panl_2025_5/48_Mai_ann_utf.pdf.
Fast neutron detection requires application of the detector material that is rich in hydrogen with a sufficient level of detection efficiency and the capability to discriminate neutron signals in the presence of undesirable gamma-ray background. In this work, we evaluated the performance of neutron modules with the measurement of gamma sources. In particular, the light yield of the detectors was calibrated with a set of standard &sup(22)Na, &sup(137)Cs and &sup(241)Am sources by the use of Compton edge technique. In the meanwhile, the time resolution was estimated by measuring gamma–gamma coincidences with &sup(60)Co source
Спец.(статьи,препринты) = С 344.1л - Нейтронные детекторы. Спектрометры. Монохроматоры
ОИЯИ = ОИЯИ (JINR)2025
Mai, A.
Calibration Technique for Stilbene-Based Neutron Detector : Abstract / A.Mai, M.S.Golovkov, A.A.Bezbakh, G.Kaminski, R.Turar // Физика элементарных частиц и атомного ядра. Письма. – 2025. – Т. 22, № 5. – P. 1032. – URL: https://www1.jinr.ru/Pepan_letters/panl_2025_5/48_Mai_ann_utf.pdf.
Fast neutron detection requires application of the detector material that is rich in hydrogen with a sufficient level of detection efficiency and the capability to discriminate neutron signals in the presence of undesirable gamma-ray background. In this work, we evaluated the performance of neutron modules with the measurement of gamma sources. In particular, the light yield of the detectors was calibrated with a set of standard &sup(22)Na, &sup(137)Cs and &sup(241)Am sources by the use of Compton edge technique. In the meanwhile, the time resolution was estimated by measuring gamma–gamma coincidences with &sup(60)Co source
Спец.(статьи,препринты) = С 344.1л - Нейтронные детекторы. Спектрометры. Монохроматоры
ОИЯИ = ОИЯИ (JINR)2025
На полку