Поиск :
Личный кабинет :
Электронный каталог: Rozhkov, V. - Characterization of Micro-SPECT System Based on Timepix Detector
Rozhkov, V. - Characterization of Micro-SPECT System Based on Timepix Detector

Статья
Автор: Rozhkov, V.
Natural Science Review: Characterization of Micro-SPECT System Based on Timepix Detector
б.г.
ISBN отсутствует
Автор: Rozhkov, V.
Natural Science Review: Characterization of Micro-SPECT System Based on Timepix Detector
б.г.
ISBN отсутствует
Статья
Rozhkov, V.
Characterization of Micro-SPECT System Based on Timepix Detector / V.Rozhkov, I.Hernandez, A.Leyva, A.Zhemchugov. – Text : electronic // Natural Science Review. – 2025. – Vol. 2, No. 3. – P. 100303. – URL: https://doi.org/10.54546/NaturalSciRev.100303. – Bibliogr.: 20.
In this work, the characteristics of a prototype SPECT system based on the Timepix readout chip, with a MURA-type encoding mask, were evaluated. The setup has a small FoV and can be used in preclinical studies of drugs on small laboratory animals. Despite many existing test protocols developed and described in pertinent documents of national standard bodies and IAEA recommendations, they are not suitable for microtomographic systems based on semiconductor pixel detectors due to different detector technology, high spatial resolution and small area of interest. To measure their characteristics, special phantoms were developed, with a small “hot region”. Such micro-SPECT parameters as spatial resolution, contrast, linearity, and system efficiency were studied using 99mTc source. The detector calibration and data preprocessing are described.
ОИЯИ = ОИЯИ (JINR)2025
Спец.(статьи,препринты) = С 344.1 - Методы и аппаратура для регистрации элементарных частиц и фотонов$
Rozhkov, V.
Characterization of Micro-SPECT System Based on Timepix Detector / V.Rozhkov, I.Hernandez, A.Leyva, A.Zhemchugov. – Text : electronic // Natural Science Review. – 2025. – Vol. 2, No. 3. – P. 100303. – URL: https://doi.org/10.54546/NaturalSciRev.100303. – Bibliogr.: 20.
In this work, the characteristics of a prototype SPECT system based on the Timepix readout chip, with a MURA-type encoding mask, were evaluated. The setup has a small FoV and can be used in preclinical studies of drugs on small laboratory animals. Despite many existing test protocols developed and described in pertinent documents of national standard bodies and IAEA recommendations, they are not suitable for microtomographic systems based on semiconductor pixel detectors due to different detector technology, high spatial resolution and small area of interest. To measure their characteristics, special phantoms were developed, with a small “hot region”. Such micro-SPECT parameters as spatial resolution, contrast, linearity, and system efficiency were studied using 99mTc source. The detector calibration and data preprocessing are described.
ОИЯИ = ОИЯИ (JINR)2025
Спец.(статьи,препринты) = С 344.1 - Методы и аппаратура для регистрации элементарных частиц и фотонов$