Поиск :
Личный кабинет :
Электронный каталог: Zel, I. Yu. - Modeling the Influence of the Geometrical Unsharpness on the Neutron Radiography and Tomography I...
Zel, I. Yu. - Modeling the Influence of the Geometrical Unsharpness on the Neutron Radiography and Tomography I...

Статья
Автор: Zel, I. Yu.
Компьютерная оптика: Modeling the Influence of the Geometrical Unsharpness on the Neutron Radiography and Tomography I...
б.г.
ISBN отсутствует
Автор: Zel, I. Yu.
Компьютерная оптика: Modeling the Influence of the Geometrical Unsharpness on the Neutron Radiography and Tomography I...
б.г.
ISBN отсутствует
Статья
Zel, I.Yu.
Modeling the Influence of the Geometrical Unsharpness on the Neutron Radiography and Tomography Images of Porous Materials / I.Yu.Zel. – Text : electronic // Компьютерная оптика. – 2025. – Т. 49, № 2. – P. 327-333. – URL: https://doi.org/10.18287/2412-6179-CO-1478. – Bibliogr.: 33.
Beam divergence is one of the instrument resolution parameters in neutron computed tomography. In pinhole geometry, due to the finite size of the source, geometric unsharpness affects the transmission images and therefore influences the reconstructed data. In this paper, we propose an approach for deterministic simulation of this effect for a voxelized 3D object. The idea behind the proposed approach is to use multiple point sources at a pinhole position and collect transmission images from each of them. The implementation was done using the ASTRA toolbox by calculating cone beam projections from each point source. This approach was applied to a porous phantom. Artifacts associated with beam divergence were identified in the reconstructed data. The influence of beam divergence on the segmentation of pores by binarization of the reconstructed data has been considered.
Спец.(статьи,препринты) = С 342 г1 - Замедление и диффузия нейтронов. Дифракция
ОИЯИ = ОИЯИ (JINR)2025
Бюллетени = 27/025
Zel, I.Yu.
Modeling the Influence of the Geometrical Unsharpness on the Neutron Radiography and Tomography Images of Porous Materials / I.Yu.Zel. – Text : electronic // Компьютерная оптика. – 2025. – Т. 49, № 2. – P. 327-333. – URL: https://doi.org/10.18287/2412-6179-CO-1478. – Bibliogr.: 33.
Beam divergence is one of the instrument resolution parameters in neutron computed tomography. In pinhole geometry, due to the finite size of the source, geometric unsharpness affects the transmission images and therefore influences the reconstructed data. In this paper, we propose an approach for deterministic simulation of this effect for a voxelized 3D object. The idea behind the proposed approach is to use multiple point sources at a pinhole position and collect transmission images from each of them. The implementation was done using the ASTRA toolbox by calculating cone beam projections from each point source. This approach was applied to a porous phantom. Artifacts associated with beam divergence were identified in the reconstructed data. The influence of beam divergence on the segmentation of pores by binarization of the reconstructed data has been considered.
Спец.(статьи,препринты) = С 342 г1 - Замедление и диффузия нейтронов. Дифракция
ОИЯИ = ОИЯИ (JINR)2025
Бюллетени = 27/025