Поиск :
Личный кабинет :
Электронный каталог: Rozhkov, V. A. - Timepix Pixel Detector Data Preprocessing for Single-Photon Emission Computed Tomography
Rozhkov, V. A. - Timepix Pixel Detector Data Preprocessing for Single-Photon Emission Computed Tomography
Книга (аналит. описание)
Автор: Rozhkov, V. A.
8th International Conference on X-Ray, Electrovacuum and Biomedical Technique, Saint Petersburg, Russia, 25–26 November 2021 [Electronic resource]: Timepix Pixel Detector Data Preprocessing for Single-Photon Emission Computed Tomography
б.г.
ISBN отсутствует
Автор: Rozhkov, V. A.
8th International Conference on X-Ray, Electrovacuum and Biomedical Technique, Saint Petersburg, Russia, 25–26 November 2021 [Electronic resource]: Timepix Pixel Detector Data Preprocessing for Single-Photon Emission Computed Tomography
б.г.
ISBN отсутствует
Книга (аналит. описание)
Rozhkov, V.A.
Timepix Pixel Detector Data Preprocessing for Single-Photon Emission Computed Tomography / V.A.Rozhkov, A.S.Zhemchugov, P.I.Smolyansky, A.Leyva // 8th International Conference on X-Ray, Electrovacuum and Biomedical Technique, Saint Petersburg, Russia, 25–26 November 2021 [Electronic resource] / Ed.: N.N.Potrakhov, A.Yu.Gryaznov, D.K.Kostrin. – New York : AIP, 2023. – P. 020019. – URL: https://doi.org/10.1063/5.0134345. – Bibliogr.: 9.
This paper describes the methodology and data preprocessing results of a micro-SPECT system with a field of view of 57 mm x 57 mm. The preprocessing can significantly reduce noise that affects image reconstruction. The tomographic spatial resolution calculated using phantoms is. 2.5 mm. System alignment and accurate geometric positioning allow to increase significantly the system spatial resolution. – (AIP Conference Proceedings ; Vol. 2726) .
ОИЯИ = ОИЯИ (JINR)2023
Спец.(статьи,препринты) = С 344.1м - Полупроводниковые детекторы
Спец.(статьи,препринты) = Ц 846 - Оптико-электронные системы обработки информации
Rozhkov, V.A.
Timepix Pixel Detector Data Preprocessing for Single-Photon Emission Computed Tomography / V.A.Rozhkov, A.S.Zhemchugov, P.I.Smolyansky, A.Leyva // 8th International Conference on X-Ray, Electrovacuum and Biomedical Technique, Saint Petersburg, Russia, 25–26 November 2021 [Electronic resource] / Ed.: N.N.Potrakhov, A.Yu.Gryaznov, D.K.Kostrin. – New York : AIP, 2023. – P. 020019. – URL: https://doi.org/10.1063/5.0134345. – Bibliogr.: 9.
This paper describes the methodology and data preprocessing results of a micro-SPECT system with a field of view of 57 mm x 57 mm. The preprocessing can significantly reduce noise that affects image reconstruction. The tomographic spatial resolution calculated using phantoms is. 2.5 mm. System alignment and accurate geometric positioning allow to increase significantly the system spatial resolution. – (AIP Conference Proceedings ; Vol. 2726) .