Поиск :
Личный кабинет :
Электронный каталог: Atanov, N. - Crystal Calorimetry for Charged Lepton Flavor Violation Searches
Atanov, N. - Crystal Calorimetry for Charged Lepton Flavor Violation Searches

Книга (аналит. описание)
Автор: Atanov, N.
3rd Italian Workshop on Physics at High Energy (WIFAI2024), Bologna, Italy, 12-15 November 2024: Crystal Calorimetry for Charged Lepton Flavor Violation Searches
б.г.
ISBN отсутствует
Автор: Atanov, N.
3rd Italian Workshop on Physics at High Energy (WIFAI2024), Bologna, Italy, 12-15 November 2024: Crystal Calorimetry for Charged Lepton Flavor Violation Searches
б.г.
ISBN отсутствует
Книга (аналит. описание)
Atanov, N.
Crystal Calorimetry for Charged Lepton Flavor Violation Searches / N.Atanov, V.Baranov, Yu.I.Davydov, V.Glagolev, [a.o.]. – Text : electronic // 3rd Italian Workshop on Physics at High Energy (WIFAI2024), Bologna, Italy, 12-15 November 2024 / Ed.: S.Perazzini, A.Cervelli, F.Ferrari, M.Fontana. – Trieste : SISSA, 2025. – P. 1-9. – URL: https://pos.sissa.it/489/030/pdf. – Bibliogr.: 8.
The Mu2e experiment at Fermilab aims to search for Charged Lepton Flavor Violation (CLFV) through the coherent conversion of a muon into an electron in the field of an aluminum nucleus. This process, highly suppressed in the Standard Model, would clearly indicate new physics if observed. A crucial component of Mu2e is its electromagnetic calorimeter, which enhances the identification and measurement of conversion electrons. The calorimeter consists of two disks of undoped CsI crystals read out by custom-designed SiPMs and fast front-end electronics. This paper presents an overview of the calorimeter’s design, its custom SiPM technology, the readout and data acquisition system, and the results from commissioning tests. Building on the experience from Mu2e, the proposed Mu2e-II upgrade aims to enhance further the experiment’s sensitivity by an order of magnitude. This requires significant advancements in calorimeter technology, particularly in crystal materials and photodetector performance. Studies on BaF2 and LYSO crystals, as well as the development of radiation-hard Silicon Photomultipliers (SiPMs), are currently underway. Test beam results demonstrate promising improvements in energy resolution and timing capabilities, ensuring the feasibility of next-generation calorimetry solutions for Mu2e-II – (Proceedings of Science ; Vol. 489) .
Спец.(статьи,препринты) = С 344.1с1 - Ливневые спектрометры полного поглощения. Адронные калориметры
Спец.(статьи,препринты) = С 344.1м - Полупроводниковые детекторы
ОИЯИ = ОИЯИ (JINR)2025
Atanov, N.
Crystal Calorimetry for Charged Lepton Flavor Violation Searches / N.Atanov, V.Baranov, Yu.I.Davydov, V.Glagolev, [a.o.]. – Text : electronic // 3rd Italian Workshop on Physics at High Energy (WIFAI2024), Bologna, Italy, 12-15 November 2024 / Ed.: S.Perazzini, A.Cervelli, F.Ferrari, M.Fontana. – Trieste : SISSA, 2025. – P. 1-9. – URL: https://pos.sissa.it/489/030/pdf. – Bibliogr.: 8.
The Mu2e experiment at Fermilab aims to search for Charged Lepton Flavor Violation (CLFV) through the coherent conversion of a muon into an electron in the field of an aluminum nucleus. This process, highly suppressed in the Standard Model, would clearly indicate new physics if observed. A crucial component of Mu2e is its electromagnetic calorimeter, which enhances the identification and measurement of conversion electrons. The calorimeter consists of two disks of undoped CsI crystals read out by custom-designed SiPMs and fast front-end electronics. This paper presents an overview of the calorimeter’s design, its custom SiPM technology, the readout and data acquisition system, and the results from commissioning tests. Building on the experience from Mu2e, the proposed Mu2e-II upgrade aims to enhance further the experiment’s sensitivity by an order of magnitude. This requires significant advancements in calorimeter technology, particularly in crystal materials and photodetector performance. Studies on BaF2 and LYSO crystals, as well as the development of radiation-hard Silicon Photomultipliers (SiPMs), are currently underway. Test beam results demonstrate promising improvements in energy resolution and timing capabilities, ensuring the feasibility of next-generation calorimetry solutions for Mu2e-II – (Proceedings of Science ; Vol. 489) .
Спец.(статьи,препринты) = С 344.1с1 - Ливневые спектрометры полного поглощения. Адронные калориметры
Спец.(статьи,препринты) = С 344.1м - Полупроводниковые детекторы
ОИЯИ = ОИЯИ (JINR)2025
На полку