Поиск :
Личный кабинет :
Электронный каталог: Togtokhtur, T. - Contrast Enhancement Calculation of X-Ray Imaging
Togtokhtur, T. - Contrast Enhancement Calculation of X-Ray Imaging

Статья
Автор: Togtokhtur, T.
Физика элементарных частиц и атомного ядра. Письма: Contrast Enhancement Calculation of X-Ray Imaging : Abstract
б.г.
ISBN отсутствует
Автор: Togtokhtur, T.
Физика элементарных частиц и атомного ядра. Письма: Contrast Enhancement Calculation of X-Ray Imaging : Abstract
б.г.
ISBN отсутствует
Статья
Togtokhtur, T.
Contrast Enhancement Calculation of X-Ray Imaging : Abstract / T.Togtokhtur, E.B.Dushanov, M.Batmunkh, A.N.Bugay // Физика элементарных частиц и атомного ядра. Письма. – 2025. – Т. 22, № 5. – P. 1066. – URL: https://www1.jinr.ru/Pepan_letters/panl_2025_5/62_Togtokhtur_ann_utf.pdf.
A computed tomography (CT) scan has been improved to clarify the tumor sites and size by utilizing radiocontrast media in medical X-ray imaging techniques. In particular, well-tolerated contrast images of a phantom containing mixtures of contrast agents, such as iodine and gadolinium, have absorbed the photons highly. In this work, the effect of a two-dimensional projection image of an imaging phantom adapted to a preclinical experimental setup containing mixtures of contrast agents depending on their concentration, distribution and materials was evaluated using the Monte Carlo method. The projection image produced from the calculation demonstrated different tolerances for each iodine concentration, and the brightest part corresponded to the rod with the highest concentration. However, it could not be demonstrated well in the shorter targets. Nevertheless, the image tolerance on the target with the iodinated shell was brighter than the uniform distribution due to increased iodine volume density. As a result, the calculation could be given to find the optimal distribution of the iodine in biological objects for Х-ray imaging. Finally, this study indicates the perspective of enhanced CT on targeted sites of imaging phantom-filled soft tissue (ICRP) at potential concentrations within a safe range of iodine without difficulty
Спец.(статьи,препринты) = С 349 д - Биологическое действие излучений$
ОИЯИ = ОИЯИ (JINR)2025
Togtokhtur, T.
Contrast Enhancement Calculation of X-Ray Imaging : Abstract / T.Togtokhtur, E.B.Dushanov, M.Batmunkh, A.N.Bugay // Физика элементарных частиц и атомного ядра. Письма. – 2025. – Т. 22, № 5. – P. 1066. – URL: https://www1.jinr.ru/Pepan_letters/panl_2025_5/62_Togtokhtur_ann_utf.pdf.
A computed tomography (CT) scan has been improved to clarify the tumor sites and size by utilizing radiocontrast media in medical X-ray imaging techniques. In particular, well-tolerated contrast images of a phantom containing mixtures of contrast agents, such as iodine and gadolinium, have absorbed the photons highly. In this work, the effect of a two-dimensional projection image of an imaging phantom adapted to a preclinical experimental setup containing mixtures of contrast agents depending on their concentration, distribution and materials was evaluated using the Monte Carlo method. The projection image produced from the calculation demonstrated different tolerances for each iodine concentration, and the brightest part corresponded to the rod with the highest concentration. However, it could not be demonstrated well in the shorter targets. Nevertheless, the image tolerance on the target with the iodinated shell was brighter than the uniform distribution due to increased iodine volume density. As a result, the calculation could be given to find the optimal distribution of the iodine in biological objects for Х-ray imaging. Finally, this study indicates the perspective of enhanced CT on targeted sites of imaging phantom-filled soft tissue (ICRP) at potential concentrations within a safe range of iodine without difficulty
Спец.(статьи,препринты) = С 349 д - Биологическое действие излучений$
ОИЯИ = ОИЯИ (JINR)2025
На полку